- Drill 4 holes as shown: 108 × 59 mm.
- Use all 4 screws (Ø 6.6 mm holes).
- The mount must carry 6.2 kg plus the forces of the movement and the sea.
- Point the connectors so the cables have room and no water runs into them.
Wire it
CautionWrong polarity damages the system. Switch off the power before you start.
- Power: 24 V DC, minimum 4 A, with a dedicated breaker and fuse.
- On/off: Sentry has no switch. Use the remote switch of the DC-DC converter (A02871). It needs only a small low-power switch.
- Power cable (A02233): 10 m. Do not extend it. Extend the line between battery and DC-DC converter instead. Mind the voltage drop.
- Data cable (A02232): 10 m to the router. Extend with the Ethernet coupler (A00630) and Cat 5e or better. Maximum 100 m in total. At least 100 Mbit/s.


Good cabling
- No kinks, no sharp edges. Use strain relief.
- Drip loops and service loops. Water must not run to the connectors.
- Marine-grade, sealed connections. Away from heat and moving parts.
- Check cables and connectors regularly, especially where it vibrates.